deck board stress capacity

residential wood deck construction guide - city of farmington hills

michigan communities: the following contractors & suppliers support this wood deck construction guide: shall have an allowable stress design capacity of not less than 1,500 lbs or hold down devices with an allowable stress design 【Get Price】

deck guidelines - town of ellington

american wood council has created a deck building guide based on this code. if structure is typical wood frame on continuous foundation without any cantilever then ledger stress design capacity of not less than 1500 pounds (6672 n).【Get Price】

residential wood deck construction guide - city of linden

wood deck. construction. guide. based on the 2015 michigan residential code. revised june 2019. e2.2.9090 shall have an allowable stress design capacity of not less than 1,500 lbs or hold down devices with an allowable 【Get Price】

deck construction - town of brookline, nh

prescriptive residential wood deck construction guide. american wood . a preservatives and retentions listed in table 1 are based on the american wood protection . capacity of 100 lbs in both uplift and lateral load.【Get Price】

tech bulletin ledger board: structural screw - grk fasteners

2442. 13. capacities are designed at 100% stress level. adjustments in stress level, such as for duration of load or wet-use conditions, may apply where permitted by code or local ordinance. 14. deck ledger boards and rim joist shall be 1” 【Get Price】

structure magazine residential wood deck design

to encourage compliant deck design and construction, the american wood council published design for code in the deck lateral loads section below, decking can provide diaphragm capacity and stiffness, but those strength and stiffness 【Get Price】

irc deck handout - town of essex, ct

prescriptive residential wood deck construction guide. american wood council wood decks that are attached to the house to resist lateral forces. allowable stress design capacity of not less than 1,500 lb. [r507.2.3].【Get Price】

prescriptive residential deck construction guide

rim joist decking ledger board fasteners existing house floor construction ledger board attachment to existing house joists post-to-beam connection .. a minimum capacity of 100 ibs in both uplift and lateral load directions. joists may also 【Get Price】

layher allround technical brochure (pdf) - telinekataja

decks can be fitted or removed at any .. stress capacity values* of the allround ledger and the diagonal brace. .. plank deck. vertical diagonal braces according to static requirement. standard scaffold assemblies according to approval do 【Get Price】

residential wood deck construction guide - semboia

17 may 2016 communities: the following contractors & suppliers support this wood deck construction guide: shall have an allowable stress design capacity of not less than 1,500 lbs or hold down devices with an allowable stress 【Get Price】

residential timber decks - qbcc

hardwood decking boards and deck framing containing for alternative sizes, spans and stress grades refer to as 1684 residential timber framed construction. for cca treated timber shall not be used for domestic decking boards. 2.【Get Price】

deck connection and fastening guide - tulalip tribes

except for hurricanes and tornadoes, more injuries may be connected to deck failures than all other wood building components and loading cases combined.” while decks are required to meet certain code standards and load capacities, it's 【Get Price】

prescriptive residential wood deck construction guide

prescriptive residential wood deck construction guide. american wood .. length/180 deflection with 220 lb point load (see figure 1a and figure 2). 4. incising allowable stress design capacity of not less than 1,500 lb.【Get Price】

residential wood deck construction guide - rochester hills

wood deck. construction. guide. based on the 2015 michigan residential code. revised may 17, 2016. e2.2.9090 shall have an allowable stress design capacity of not less than 1,500 lbs or hold down devices with an allowable 【Get Price】

calculate deck load capacity - tributary area - decksgo

calculate deck load capacity before you build your deck by understanding tributary areas and soil. once your deck starts sinking it can rip the ledger board away from the house or you will have to jack up the sunken area, excavate and pour 【Get Price】

lateral load path and capacity of exterior decks - forest products

wood design focus v. 23, n. 2. 21. brian j. parsons, donald a. bender, ph.d., p.e., j. daniel dolan, ph.d., p.e.,. robert j. tichy, ph.d., and frank e. woeste, ph.d., p.e.. lateral load path and capacity of exterior. decks. introduction.【Get Price】

residential wood deck construction guide

wood deck. construction. guide. based on the 2009 michigan residential code. the details in this document apply to residential decks only. construction shall have an allowable stress design capacity of not less than 1,500 lb.【Get Price】

design capacities for oriented strand board allowable stress

council's allowable stress deign (asd)/lrfd manual for engineered wood construction. teco has chosen to do so load capacities, which are presented here for allowable stress design (asd) (table a), are applicable to commodity osb.【Get Price】

wood deck guide updated to 2009 irc - american wood council

af&pa's prescriptive residential wood deck construction guide – dca 6 was developed in 2007 deck. specification of a load capacity of 625 pounds for the stair stringer joist hanger. reference to threaded nails versus common nails.【Get Price】

deck construction specifications

of 20' -7 ”. southern pine deck. beam maximum spans*. lumber. size. total deck joist span (including cantilever). (less than or determine the decking board thickness and direction to determine joist spacing. . stress design capacity.【Get Price】